OutSystems · Apps and SaaSMay 8, 2026, 11:56 UTC 6 months ago

Incident affecting Personal Environments for O11 and ODC

MajorPowerUpdated 4d ago
May 8, 11:56 UTCMay 11, 16:12 UTC
Duration
3d 4h
Impact
Major
Root cause
Power
OutSystems, 90 days
16 incidents
Affected
Customer Apps & DataPlatform and PortalOutSystems Personal Edition - Customer Apps & DataOutSystems Personal Edition - Platform and Portal
Status page

Final update

On May 8, 2026, at 12:03 AM UTC, ODC and O11 Personal Environments in the N. Virginia region experienced a service disruption caused by an AWS infrastructure event affecting a single Availability Zone. The disruption was related to an external power and cooling issue that impacted the availability of underlying AWS services. Customers experienced service unavailability, including issues with logging in and publishing applications.The impact was limited to O11 Personal Environments and a small subset of users, while impact on ODC remained contained. As AWS services recovered, many OutSystems environments resumed normal operation automatically. Some environments required additional recovery actions to fully restore service availability. For ODC, the incident was fully resolved on May 9, 2026, at 3:30 AM UTC. Recovery efforts for O11 Personal Environments continued afterward due to the additional complexity of restoring affected environments. All services are now operating as expected, and no user action is required.

Timeline

  1. Postmortem · May 13, 16:08 UTC
    On May 8, 2026, at 12:03 AM UTC, ODC and O11 Personal Environments in the N. Virginia region experienced a service disruption caused by an AWS infrastructure event affecting a single Availability Zone. The disruption was related to an external power and cooling issue that impacted the availability of underlying AWS services. Customers experienced service unavailability, including issues with logging in and publishing applications.The impact was limited to O11 Personal Environments and a small subset of users, while impact on ODC remained contained. As AWS services recovered, many OutSystems environments resumed normal operation automatically. Some environments required additional recovery actions to fully restore service availability. For ODC, the incident was fully resolved on May 9, 2026, at 3:30 AM UTC. Recovery efforts for O11 Personal Environments continued afterward due to the additional complexity of restoring affected environments. All services are now operating as expected, and no user action is required.
  2. Resolved · May 11, 16:12 UTC
    This incident has been fully resolved, and Personal Environments in the N. Virginia region for O11 and ODC are now operating as expected. Thank you for your patience.
  3. Monitoring · May 11, 07:29 UTC
    Based on official feedback from AWS as of May 8th, the core issue impacting ODC is mitigated and the service is now operating normally. For O11 Personal Environments, while the primary issue is resolved, some customers might still face 504 errors or access issues. A small number of instances remain impaired and AWS continues to work to recover all affected remaining resources. We will continue to closely monitor the situation and we will provide further updates when available.
  4. Monitoring · May 9, 12:23 UTC
    We have now confirmation from AWS that access is now being restored on the affected environments. We suggest that customers can start testing on their end. Some customers might still face 504 errors or access issues. We continue to closely monitor the situation and we will provide further updates when available.
  5. Monitoring · May 8, 23:19 UTC
    We have identified the root cause of the issue as a hardware failure within the AWS US East (N. Virginia) datacenter. We are actively deploying mitigations and closely monitoring AWS's recovery progress, which is expected to take several hours. Users may continue to experience symptoms while these fixes are being fully implemented.
  6. Monitoring · May 8, 16:30 UTC
    We can now confirm that impact should only be perceived on O11 Personal Environments. AWS was able to identify that the issue was caused by a thermal event. Recovery might take several hours. We will continue to investigate this issue and closely monitoring the developments on the AWS investigations.
  7. Identified · May 8, 11:56 UTC
    We are currently investigating an issue affecting O11 Personal Environments and ODC in the N. Virginia region. Customers may experience a variety of symptoms, most notably service unavailability for O11 and login/publishing issues for ODC. The cause has been identified to an issue in the AWS datacenter. We will provide an update as soon as more details are available.